Add to Cart
Customized Horizontal Inert Gas Protective Vacuum Carbonization Furnace Hot New Resistance Furnace PLC Water Nitron Cooling
The maximum temperature | 1800℃,2300℃ |
Volume at highest temperature | 0.03m3,0.05m3, 0.1m3, 0.15m3,0.2m3 ,0.3m3 |
Furnace working atmosphere | Hydrogen, nitrogen, inert gases |
Temperature Uniformity | ≤±10℃ |
Temperature measurement | Far infrared optical temperature measurement |
Temperature measurement Range | 800~2400℃或0~2400℃ |
Temperature measurement accuracy | 0.2~0.75% |
Temperature Control accuracy | ±1℃ |
Temperature control | Program control and manual control |
Ultimate heating rate | 200℃/ min (empty furnace, depending on high temperature zone volume and furnace structure) |
Characteristics:
1) Graphite heating plate to use high purity, high density and high strength graphite plate, preferably isotropic graphite plate.Because its bending strength and compression strength are 2.8 times and 3.5 times of ordinary graphite, respectively.
2)The connection technology between the power supply and the electrode is very important. The connection is firm, the contact resistance is small, it is better to use specially processed graphite bolts. The cooling of the joint is a key technology, but also often prone to accidents, processing and welding technology must be in place. At the same time, standardized operation is also one of the elements to extend the service life. Water pressure switch and alarm should be provided for shell water cooling.